Oilfield

Date:2014-03-10 16:53:26 From:

Product demand and challenges
Although there are net oil and electricity supply, but the supply is far from normal, often because of bad weather or season and other reasons to stop power line failure, high security, stability, support normal operating oil fields.
1, string, and machine function
String Machine backup function: can be used with ATS dual standby switching function automatically switches between electricity and diesel generator set or two diesel generators.
And machine expansion features: two or more specifications identical three-phase units, at rated power factor, to meet the (20-100)% of rated power stability within the scope of the parallel run. In order to improve the active and reactive power accuracy and stability of the rational allocation run, requiring diesel unit in the steady-state speed droop governor has within (2-5)% range adjustment device. In the control box (screen) in the steady-state voltage regulator allows the device to adjust the rate of adjustment in the range of 5%.
2, working conditions
Altitude can run 3000 meters;
Ambient temperature limit is -15 C °, the upper limit is 40 C °, can choose other environmental unit.
3, stable performance, high reliability
MTBF of units is not less than 2000 hours.
4, convenient refueling facilities and water conservation measures
The unit has an external fuel system and is equipped with a lock function;
Usually requires large fuel tank, which can meet 12-24 hours to run.

Solutions
Excellent performance and stable generators, low noise design, equipped with PLC-5220 control system with AMF function, ATS is connected through and to ensure that once the oil fields off the main power supply, the system must be able to provide alternative power supply immediately.

Superiority
Complete set of products, programs, and reduce the technical mastery required to make the unit easier to use and easier to maintain;
· Control system with AMF function, automatic start and automatic shutdown and alarm functions under a number of monitoring;
· Optional ATS, a small unit can be used built-in unit ATS;
· Ultra-low noise generation, to meet the daily needs;
· Stable performance, MTBF of units is not less than 2000 hours;
· Small units, matching some of the device in cold areas and high temperatures to achieve regional operational requirements;
· The special needs of some customers can be custom designed and developed.